Dust protection membrane
Advantages
- Easy to work with: robust PP fleece
- Flexible application: for dry and slightly moist fillings
- Reliable protection against dust thanks to particularly close interweaving
- For well-protected building components: particularly diffusion-open
Areas of application
For use as dust and trickle protection for rooms under ceilings with loose-fill insulation and in floors.
Technical specs
Material | |||
Fleece | 3-ply polypropylene | ||
Property | Regulation | Value | Regulation |
Colour | Grey | ||
Surface weight | EN 1849-2 | 45 g/m² ; 0.15 oz/ft² | EN 1849-2 |
Thickness | EN 1849-2 | 0.1 mm ; 4 mils | EN 1849-2 |
Water vapour resistance factor µ | EN 1931 | 300 | EN 1931 |
sd value | EN 1931 | 0.03 m | EN 1931 |
g value | 0.15 MN·s/g | ||
Vapour permeance | ASTM E 96 | 109 US perms | ASTM E 96 |
Fire class | EN 13501-1 | E | EN 13501-1 |
Tensile strength MD/CD | EN 12311-2 | 80 N/5 cm / 50 N/5 cm ; 9 lb/in / 6 lb/in | EN 12311-2 |
Temperature resistance | EN 1109, EN 1296, EN 1297 | Permanent -40 °C to 100 °C ; -40 °F to 212 °F | EN 1109, EN 1296, EN 1297 |
Thermal conductivity | 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F) |