Installation steps
1. Reliable sealing
TESCON NAIDECK mono has a very free- flowing butyl adhesive. This adhesive is pulled into the hole created when the nail or screw is installed, thus sealing this hole.
2. Stick the tape in place
Centre the nail-sealing tape on the counter batten or the exterior membrane to be sealed, and gradually stick it in place.
3. Rub the tape firmly to secure the adhesive bond
This step can be carried out in a manner that is kinder to your hands by using the pro clima PRESSFIX application tool.
4. Align and fasten the counter batten
Put the counter batten in place and fasten completely using nails or screws. The counter batten and TESCON NAIDECK mono must lie flat on the exterior membrane with sufficient pressure. You’re finished!