Hydrosafe® high-performance vapour check, suitable for all fibrous insulation mats and boards

Advantages

  • Best possible protection against moisture damage to structures and mould because this product is humidity-variable with a variation of a factor of over 100
  • Permanent protection: performance tested and certified by independent testing authority (ETA-18/1146)
  • Protected winter building sites thanks to hydrosafe® behaviour
  • Can be combined with all fibrous insulation mats and boards
  • Easy to work with: dimensionally stable, no splitting or tear propagation
  • Excellent values in hazardous substance testing, has been tested according to the ISO 16000 evaluation scheme

Areas of application

Vapour check (alternate terms: vapour control or retarder) membrane for use on roofs, walls, ceilings and floors on structures that are open or closed to diffusion on the exterior, e.g. flat/pitched roofs and green roofs, after appropriate design calculations have been carried out.

Technical specs

  Material
Fleece Polypropylene
Functional film Polyethylene copolymer
Property Value Regulation
Colour White-translucent
Surface weight 85 g/m² ; 0.28 oz/ft² EN 1849-2
Thickness 0.25 mm ; 10 mils EN 1849-2
Water vapour resistance factor µ 56 000 EN 1931
sd value 14 m EN 1931
sd value, humidity-variable 0.25 - >25 m EN ISO 12572
g value 70 MN·s/g
g value, humidity-variable 1.25 - >125 MN·s/g EN ISO 12572
Vapour permeance 0.23 perms ASTM E96-A
Vapour permeance, humidity-variable < 0.13 - 13 perms EN ISO 12572
Hydrosafe value (sd) 2 m DIN 68800-2
Surface burning characteristics Class A (Flame Spread 0; Smoke development index 35) ASTM E84
Fire class E EN 13501-1
Airtightness ≤ 0.004 cfm/ft² ASTM E2178
Airtightness Tested EN 12114
Tensile strength MD/CD 110 N/5 cm / 80 N/5 cm ; 13 lb/in / 9 lb/in EN 12311-2
Elongation MD/CD 40% / 35% EN 12311-2
Nail tear resistance MD/CD 60 N / 60 N ; 13 lbf / 13 lbf EN 12310-1
Durability after artificial ageing Passed ETA-18/1146
Temperature resistance Permanent -40 °C to 80 °C ; -40 °F to 176 °F EN 1109, EN 1296, EN 1297
Thermal conductivity 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F)
CE labelling Yes ETA-18/1146