Roofing underlay membrane with 3D separation mesh and self-adhesive strips

Advantages

  • Highest possible durability and thermostability thanks to the TEEE membrane
  • Reliable drying out: highly permeable (sd value = 0.05 m ; g value = 0.25 MN·s/g ; 65 US perms)
  • Protects against corrosion and ensures improved noise insulation thanks to the 3D separation mesh
  • Dry building components thanks to pore-free TEEE membrane that is resistant to driving rain
  • Up to 3 months of outdoor exposure
  • Quick and reliable adhesion thanks to the integrated ‘connect’ self-adhesive strips on the long edges of the membrane

Areas of application

For use as a roofing underlay or facade membrane for ventilated and non-ventilated structures in combination with all roof and facade materials such as titanium zinc, aluminium, stainless steel, galvanised steel, copper etc. Fibrous membranes offer greater protection for structures and are recommended by leading providers of metal roofs for this reason. The 8 mm (5/16”) thick 3D separation mesh made of fibrous PP protects the covering against waterlogging and dampens noise caused by rain or hail.

Technical specs

  Material
Structured underlay Polypropylene
Protective and covering fleece Polypropylene microfibre
Functional film Monolithic TEEE
Self-adhesive strips Butyl rubber
Property Value Regulation
Colour Anthracite
Surface weight 420 g/m² ; 1.38 oz/ft² EN 1849-2
Thickness 8.0 mm ; 315 mils EN 1849-2
Water vapour resistance factor µ 6 EN ISO 12572
sd value 0.05 m EN ISO 12572
g value 0.25 MN·s/g
Vapour permeance 38 perms ASTM E 96
Fire class E EN 13501-1
Outdoor exposure 3 months
Watertight joints with ‘connect’ adhesive strips or TESCON VANA tape W1 EN 13859-1
Water column 10 000 mm ; 32' 10" EN ISO 811
Watertightness, non-aged/aged* W1 / W1 EN 13859-1
Tensile strength MD/CD 220 N/5 cm / 170 N/5 cm ; 25 lb/in / 19 lb/in EN 13859-1 (A)
Tensile strength MD/CD, aged* 185 N/5 cm / 160 N/5 cm ; 21 lb/in / 18 lb/in EN 13859-1 (A)
Elongation MD/CD 60% / 70% EN 13859-1 (A)
Elongation MD/CD, aged* 40% / 50% EN 13859-1 (A)
Nail tear resistance MD/CD 130 N / 135 N ; 29 lbf / 30 lbf EN 13859-1 (B)
*) Durability after artificial ageing Passed EN 1297 / EN 1296
Flexibility at low temperature -40 °C ; -40 °F EN 1109
Temperature resistance Permanent -40 °C to 100 °C ; -40 °F to 212 °F EN 1109, EN 1296, EN 1297
Thermal conductivity 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F)
CE labelling Yes EN 13859-1