Full-surface adhesive sealing strip

SOLTEMPA

Advantages

  • Very long service life: UV ageing test carried out with 10 000 h instead of 336 h
  • Permanent protection thanks to the high resistance to ageing and heat of the TEEE membrane
  • Easy and reliable installation thanks to its split release film
  • Sticks immediately to subsurfaces that have sufficient stability
  • Flexible use: can also be used on facades
  • Maximal flexibility in planning construction schedules thanks to up to 6 months of outdoor exposure during the construction phase

Areas of application

Eave membrane for installation on SOLITEX WELDANO for open eave ends with a perforated plate. Allows for drainage of the roof lining into the gutters.

Split of the release film

Strip width Split (approx.)
280 mm (11") 30 | 250 mm (1 3/16" | 9 13/16")

Technical specs

  Material
Fleece Polypropylene microfibre
Membrane Monolithic TEEE
Fleece Polypropylene microfibre
Membrane Monolithic TEEE
Fleece Polypropylene microfibre
Adhesive Special acrylate adhesive
Release film Silicone-coated PE film
Property Value Regulation
Colour black
Surface weight 390 g/m² ; 1.28 oz/ft² EN 1849-2
Thickness 1.1 mm ; 43 mils EN 1849-2
Water vapour resistance factor µ 185 EN ISO 12572
sd value 0.2 m EN ISO 12572
g value 1 MN·s/g
Vapour permeance 16.4 US perms
Fire rating E EN 13501-1
Outdoor exposure 6 months, permanent against diffuse UV light in the eave area
Water column 10 000 mm ; 32' 10" EN ISO 811
Watertightness, non-aged/aged* W1 / W1 EN 13859-1
Tensile strength MD/CD 480 N/5 cm / 340 N/5 cm ; 55 lb/in / 39 lb/in EN 13859-1 (A)
Tensile strength MD/CD, aged* 360 N/5 cm / 260 N/5 cm ; 41 lb/in / 30 lb/in EN 13859-1 (A)
Elongation MD/CD 60 % / 70 % EN 13859-1 (A)
Elongation MD/CD, aged* 45 % / 50 % EN 13859-1 (A)
Nail tear resistance MD/CD 300 N / 380 N ; 67 lbf / 85 lbf EN 13859-1 (B)
*) Durability after artificial ageing with 10,000 h of UV ageing instead of 5,000 h passed EN 1297 / EN 1296
Flexibility at low temperature -40 °C ; -40 °F EN 1109
Temperature resistance permanent -40 °C to 100 °C ; -40 °F to 212 °F
Thermal conductivity 0.04 W/(m·K)
CE labelling yes EN 13859-1