Vapour check membrane for external insulation and roof refurbishment, with self-adhesive strips
Advantages
- Protects building structures against weathering during the construction phase for roof pitches of 10° (2.1:12) and higher
- Water-resistant and waterproof, can be walked on
- Acts as a vapour check and airtightness layer simultaneously
- Excellent values in hazardous substance testing, has been tested according to the ISO 16000 evaluation scheme
- Quick and reliable adhesion thanks to the integrated ‘connect’ self-adhesive strips on the long edges of the membrane
Areas of application
For use as a vapour check membrane and airtight membrane directly on top of sheathing underneath suitable external roof insulation made of all insulation materials on structures that are open to diffusion on the exterior (roofing underlay with SOLITEX MENTO 3000, for example).
In addition, DA connect can be used as an airtight membrane and refurbishment vapour check between two layers of insulation. All fibrous insulation materials can be used for insulation installed between rafters; the external roof insulation must be a foam insulation material (e.g. consisting of PUR, PIR or EPS). Please contact Technical Support at pro clima in Germany for assistance with calculating the thickness of the external foam insulation that is required from a building physics viewpoint. If necessary, the outer sealing layer should be implemented using a diffusion-open roofing underlay membrane (e.g. SOLITEX MENTO 3000).
Technical specs
Material | |||
Protective and covering fleece | Polypropylene | ||
Functional film | Polypropylene | ||
Self-adhesive strips | Water-resistant SOLID adhesive | ||
Property | Regulation | Value | Regulation |
Colour | Green | ||
Surface weight | EN 1849-2 | 130 g/m² ; 0.43 oz/ft² | EN 1849-2 |
Thickness | EN 1849-2 | 0.45 mm ; 18 mils | EN 1849-2 |
Water vapour resistance factor µ | EN 1931 | 5 000 | EN 1931 |
sd value | EN 1931 | 2.30 m | EN 1931 |
g value | 11.5 MN·s/g | ||
Vapour permeance | ASTM E 96 | 1.4 perms | ASTM E 96 |
Fire class | EN 13501-1 | E | EN 13501-1 |
Outdoor exposure | 3 months | ||
Outdoor exposure for refurbishment betw. 2 insulation layers | 14 days ; 7 days at ≤10 °C (≤50 °F) | ||
Watertight joints with ‘connect’ adhesive strips or TESCON VANA tape | EN 13859-1 | W1 | EN 13859-1 |
Watertightness to liquid water | EN 1928 | W1 | EN 1928 |
Water column | EN ISO 811 | > 2 500 mm ; > 8' 2" | EN ISO 811 |
Airtightness | EN 12114 | Tested | EN 12114 |
Tensile strength MD/CD | EN 12311-2 | 230 N/5 cm / 200 N/5 cm ; 26 lb/in / 23 lb/in | EN 12311-2 |
Elongation MD/CD | EN 12311-2 | 90% / 90% | EN 12311-2 |
Nail tear resistance MD/CD | EN 12310-1 | 120 N / 115 N ; 27 lbf / 26 lbf | EN 12310-1 |
Durability after artificial ageing | EN 1296 / EN 1931 | Passed | EN 1296 / EN 1931 |
Temperature resistance | Permanent -40 °C to 100 °C ; -40 °F to 212 °F | ||
Thermal conductivity | 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F) | ||
CE labelling | EN 13984 | Yes | EN 13984 |